+48 22 313 22 66

Medima Infusion Pumps

The growing need to use an increasing number of medical equipment in direct vicinity of the patient demands special solutions.

 

Comprehensive Medima solutions ensure adequate safety, with pumps attachable to standard columns and stands and also suitable for docking stations (no dismantling or any additional elements are needed).

 

Docked pumps establish automatic link with MedimaNet Server which allows to monitor current infusions, store data and link with the hospital information system. Our pumps are also suitable for transport purposes.

Medima Syringe Infusion Pumps

Medima S

Basic model, extremely simple to use. Operates in: ml/min, ml/h and ml/24h.

Calculates flow rate basing on volume and delivery time.

In addition, can store in memory up to 120 drug names. Displays one throughout infusion.

 

Medima S1

Infusion flow rate programmable in ml/h and other frequently used units including: ng, µg, mg, µU, mU, U, kU, µmol, mmol, mol, / kg / min, h, 24 h.

Numerous infusion modes such as: continuous infusion, intermittent infusion, infusion with profile (up to 24 cycles).

In addition, can store in memory a drug library of 120 full drug dosing protocols, but without infusion parameter limits. Displays drug name throughout infusion.

Comprehensive configuration options: advanced protection system, night mode, alarm options.

 

Medima S2

All options of Medima S1 plus drug library with limits applicable to all infusion parameters.

Soft limits (min max) warn when recommended values are exceeded but do not prohibit the introduction of changes. Hard limits (min max) disable introduction of any values from outside prescribed range.

 

Medima S-PCA

Designed to fight against acute pain. Equipped with a patient-operated button which starts the delivery of programmed drug dose and a syringe cover with a lock.

 

An option to switch to standard infusion modes same as for model S2.

All options of Medima S2 including drug library with infusion parameter limits.

Versions with or without syringe cover.

Basic functions

 

All Medina pumps are operated in the same manner (differences between models considered) and have a number of common features:

 

Large and legible graphic display which constantly displays:

• Name of the medicine

• Flow rate

• Power status and power supply type

• Infusion pressure and preset occlusion alarm level

• Size and type of syringe

• Syringe Pump Display

 

Wide range of syringes can be selected from all major brands of the following sizes: 5, 10, 20, 30, 50 ml.

 

Automatic syringe loading and recognition simplifying and speeding up pump maintenance, reducing the initial infusion errors.

 

Simple to set up and easy to operate. Quick data entry with the use of numerical keyboard. All parameters can be adjusted without infusion interruption.

 

Different infusion units ng, µg, mg, µU, mU, U, kU, µmol, mmol, mol, / kg / min / hour / 24h.

 

Data lock. Programmed parameters can be password-protected. Additionally sophisticated function protection system allows blocking access to chosen functions, i.e. infusion start, bolus start, occlusion threshold change, pump switching-off.

 

Bolus fully automatic and manual. Possibility of programming dose, time or flow rate.

 

Automatic reduction of residual bolus after occlusion release.

 

6 levels of occlusion pressure. Possibility to adjust the pressure level during infusion. Pressure indication displayed constantly during delivery.

 

Sophisticated system of alarms. Allows different tones and loudness. Built in night mode with the option to set lower sound level as well as reduce display brightness.

 

Event log. Allows storing full infusion history (parameters, operator activities and alarms along with the date and time of occurrence). The stored information can be viewed either on the pump's display or on PC.

 

Drug library. Up to 120 drug dosing procedures can be stored in pump's memory along with all the essential infusion parameters. Additionally upper and lower, soft and hard limits for all infusion parameters can be entered in a drug library to minimize medications errors and ensure overdose protection. Soft limits warn about exceeding recommended values, but do not block values entered. Hard limits prevent from entering values that are beyond the range. The drug library can be entered as follows:

• directly from the pump keyboard

• sent from pump to pump by RS232 interface

• created in Medima Drug Editor software and set to the pump directly from a PC or via MedimaNet

Medima Volumetric Infusion Pumps

Our pumps use IV sets without silicon inlay. The use of original Medima sets guarantees high accuracy, even for very long infusions. In addition, the sets are equipped with automatic free flow blocking system to increase infusion safety, removable only when the blocking system is on. 

 

Medima P

Basic model, extremely simple to use. Operates in: ml/min, ml/h and ml/24h.

Calculates flow rate basing on volume and delivery time.

In addition, can store in memory up to 120 drug names. Displays one throughout infusion.

Micro-infusion - flow rate from 0.1 ml/h

 

Medima P1

Infusion flow rate programmable in ml/h and other frequently used units including: ng, µg, mg, µU, mU, U, kU, µmol, mmol, mol, / kg / min, h, 24 h.

Numerous infusion modes such as: continuous infusion, intermittent infusion, infusion with profile (up to 24 cycles).

In addition, can store in memory a drug library of 120 full drug dosing protocols, but without infusion parameter limits.

Displays drug name throughout infusion.

Comprehensive configuration options: advanced protection system, night mode, alarm options.

Micro-infusion - flow rate from 0.1 ml/h

Medima P2

All options of Medima P1 plus drug library with limits applicable to all infusion parameters.

Soft limits (min max) warn when recommended values are exceeded but do not prohibit the introduction of changes. Hard limits (min max) disable introduction of any values from outside prescribed range.

Basic functions

 

All Medina pumps are operated in the same manner (differences between models considered) and have a number of common features:

 

Large and legible graphic display which constantly displays:

• Name of the medicine

• Flow rate

• Power status and power supply type

• Infusion pressure and preset occlusion alarm level

• Volumetric Pump Display

 

Simple to set up and easy to operate. Quick data entry with the use of numerical keyboard. All parameters can be adjusted without infusion interruption.

 

Different infusion units ng, µg, mg, µU, mU, U, kU, µmol, mmol, mol, / kg / min / hour / 24h.

 

Data lock. Programmed parameters can be password-protected. Additionally sophisticated function protection system allows blocking access to chosen functions, i.e. infusion start, bolus start, occlusion threshold change, pump switching-off.

 

Bolus fully automatic and manual. Possibility of programming dose, time or flow rate.

 

Automatic reduction of residual bolus after occlusion release.

 

4 levels of occlusion pressure. Possibility to adjust the pressure level during infusion. Pressure indication displayed constantly during delivery.

 

Sophisticated system of alarms. Allows different tones and loudness. Built in night mode with the option to set lower sound level as well as reduce display brightness.

 

Event log. Allows storing full infusion history (parameters, operator activities and alarms along with the date and time of occurrence). The stored information can be viewed either on the pump's display or on PC.

 

Drug library. Up to 120 drug dosing procedures can be stored in pump's memory along with all the essential infusion parameters. Additionally upper and lower, soft and hard limits for all infusion parameters can be entered in a drug library to minimize medications errors and ensure overdose protection. Soft limits warn about exceeding recommended values, but do not block values entered. Hard limits prevent from entering values that are beyond the range. The drug library can be entered as follows:

• directly from the pump keyboard

• sent from pump to pump by RS232 interface

• created in Medima Drug Editor software and set to the pump directly from a PC or via MedimaNet

MEDIMA © 2015    •    Privacy Policy 

Sales Department

Tel. +48 22 313 22 50, E-mail: sprzedaz@medima.com.pl

Export Department

Tel. +48 22 313 22 60, E-mail: sales@medima.com.pl

Service Center

Tel./Fax. +48 22 313 22 57, E-mail: serwis@medima.com.pl

MEDIMA Sp. z o.o. 

Al. Jerozolimskie 200

02-486 Warszawa

NIP: 522 - 270 - 98 - 42

KRS: 0000201189

 
X
Password:
Wrong password.