+48 22 313 22 66

Family of Infusion Pumps

Sx00 / Px00

Syringe Infusion Pumps

S100

 

Basic, very simple model operating in mL/h

 

Calculates infusion rate based on the volume and time

 

• Continuous infusion mode only

 

Infusion start combined with a syringe installation takes a couple of seconds only

 

 

S200

 

•  Offers S100 capabilities

 

•  Infusion flow rate programmable in mL/h and other frequently used units:

  g, mg, µg, ng, mL, L, kJ, J, kcal, cal, mol, mmol, kIE, IE, mIE, kIU, IU, mIU, Eq, mEq, µEq /

  kg, m²/ min, h, 24h

 

Numerous infusion modes such as: continuous, intermittent, TPN and profile (up to 24

  steps and 100 cycles)

 

Comprehensive configuration options: advanced protection system, night and day

  mode, advanced alarm options

 

S300

 

• Offers S200 capabilities

 

•  One library for the whole hospital consisting of up to 40 CCAs (Clinical Care Area), up to

  40 categories, up to 5000 drugs procedures  

 

• Drug procedures including default parameters, hard and soft limits, high and low limits,

 multiple fixed concentrations, advisory notes, security functions, max. syringe etc.

 

• Additional pump configuration for each drug and CCA

 

• A number of other functions increasing infusion's safety

 

S300PCA

 

• Offers S300 capabilities

 

• Designed to fight against acute pain. Equipped with a patient-operated button which

 starts the delivery of programmed drug dose and a syringe cover with a lock

 

• An option to switch to standard infusion modes same as for the S300 model

 

• Versions with or without syringe cover

 

• Available in Q2 2018

 

S300TCI/TIVA

 

• Offers S300 capabilities

 

• Designed for anesthetic applications with built-in pharmacokinetic models of drugs

• Available in Q2 2018

Basic functions

 

All Medina pumps are operated in the same manner (differences between models considered) and have a number of common features:

 

• Large and colour display with high resolution and contrast

 

• Touch screen

 

• Alphanumeric keyboard as in cell phone

 

Wide range of world popular syringes with volumes of 2, 2.5, 3, 5, 6, 10, 12, 20, 30, 35, 50, 60 ml. Other syringes may be calibrated according to the customer’s needs

 

• Automatic syringe installation and detection simplifying and speeding up pump readiness for infusion, increasing its safety and reducing the initial infusion errors

 

• Easy to operate and intuitive interface based upon context menu which suggests only these parameters and data necessary for the particular phase of infusion setting. This solution allows to save time in order to start infusion while providing the highest standards of safety at the same time.

 

• Fast infusion start. Quick data entry with the use of alphanumerical keyboard. Its combination with touch screen gives the user several ways how parameter’s  value  can be chosen or  

  input. All parameters can be adjusted without infusion interruption.

 

• Various infusion units: g, mg, µg, ng, mL, L, kJ, J, kcal, cal, mol, mmol, kIE, IE, mIE, kIU, IU, mIU, Eq, mEq, µEq / kg, m²/ min, h, 24h

 

• Security levels. Programmed parameters can be password-protected. Additionally sophisticated function protection system allows blocking access to chosen functions, i.e. infusion

  start,  bolus start, occlusion level change, infusion stop etc.

 

• Automatic and manual bolus based on programming dose, time or flow rate. .

 

• Automatic occlusion bolus reduction (Antibolus) after occlusion alarm has been generated  

 

• 12 levels of occlusion pressure. Possibility to adjust the pressure level without infusion interruption. Intelligent occlusion avoidance algorithm. Pressure indication displayed constantly during administration

 

• Sophisticated system of alarms. Consists of three levels of priority (high, medium, low) with visual and acoustic notifications. Allows different tones, loudness and time intervals. Built-

  in night mode with the option to set lower volume level as well as reduce display brightness

 

• History of infusion. Allows storing full infusion history (parameters, operator’s activities and alarms along with the date and time of occurrence). The stored information can be viewed

  either on the pump's display or on PC.

 

Drug library. One drug library for the whole medical unit which can be automatically uploaded by Medima external software to the pumps without infusion interruption  

Volumetric Infusion Pumps

P100

 

Basic model, extremely simple to use. Enabling infusion in ml/h.

 

Calculates flow rate basing on volume and delivery time.

 

Infusion start combined with IV set installation takes a couple of seconds only.

 

P200

 

• Offers P100 capabilities

• Infusion flow rate programmable in mL/h and other frequently used units:

  g, mg, µg, ng, mL, L, kJ, J, kcal, cal, mol, mmol, kIE, IE, mIE, kIU, IU, mIU, Eq, mEq, µEq / kg,  

  m²/ min, h, 24h

• Numerous infusion modes such as: continuous, intermittent, TPN and profile (up to 24

 steps and 100 cycles)

• Comprehensive configuration options: advanced protection system, night and day mode,

  advanced alarm options

 

P300

 

• Offers P200 capabilities

• One library for the whole hospital consisting of up to 40 CCAs (Clinical Care Area), up to 40 categories, up to 5000 drugs procedures

• Drug procedures including default parameters, hard and soft limits, high and low limits, multiple fixed concentrations, advisory notes, security functions

• Additional pump configuration for each drug and CCA

• A number of other functions increasing infusion's safety

 

 

P300PCA

 

• Offers P300 capabilities

• Designed to fight against acute pain. Equipped with a patient-operated button which starts the delivery of programmed drug dose and a syringe cover with a lock

• An option to switch to standard infusion modes same as for the P300 model

• Versions with or without syringe cover

• Available in Q2 2018

 

 

P300TCI/TIVA

 

• Offers P300 capabilities

• Designed for anesthetic applications with built-in pharmacokinetic models of drugs

• Available in Q2 2018

 

 

 

Basic functions

 

All Medina pumps are operated in the same manner (differences between models considered) and have a number of common features:

 

• Large and colour display with high resolution and contrast

• Touch screen

• Alphanumeric keyboard as in cell phone

• Easy to operate and intuitive interface based upon context menu which suggests only these parameters and data necessary for the particular phase of infusion setting. This solution

  allows to save time in order to start infusion while providing the highest standards of safety at the same time.

• Fast infusion start. Quick data entry with the use of alphanumerical keyboard. Its combination with touch screen gives the user several ways how parameter’s  value  can be chosen or

  input. All parameters can be adjusted without infusion interruption.

• Various infusion units: g, mg, µg, ng, mL, L, kJ, J, kcal, cal, mol, mmol, kIE, IE, mIE, kIU, IU, mIU, Eq, mEq, µEq / kg, m²/ min, h, 24h

• Security levels. Programmed parameters can be password-protected. Additionally sophisticated function protection system allows blocking access to chosen functions, i.e. infusion

  start,  bolus start, occlusion level change, infusion stop etc.

• Automatic and manual bolus based on programming dose, time or flow rate.

• Automatic occlusion bolus reduction (Antibolus) after occlusion alarm has been generated  

• 12 levels of occlusion pressure. Possibility to adjust the pressure level without infusion interruption. Intelligent occlusion avoidance algorithm. Pressure indication displayed constantly during administration

• Sophisticated system of alarms. Consists of three levels of priority (high, medium, low) with visual and acoustic notifications. Allows different tones, loudness and time intervals. Built-

  in night mode with the option to set lower volume level as well as reduce display brightness

• History of infusion. Allows storing full infusion history (parameters, operator activities and alarms along with the date and time of occurrence). The stored information can be viewed  

  either on the pump's display or on PC

• Drug library. One drug library for the whole medical unit which can be automatically uploaded by Medima external software to the pumps without infusion interruption

• Medima Line administration sets include standard, blood, oncological, nutrition and extension sets. They are equipped with:

    o Free flow protection clamp (FFPC),

    o Roller clamp with spike handler

    o Luer Lock cap with hydrophobic filter (automatic prime stop function)

    o Rotating Luer Lock

 

MEDIMA © 2017    •   Privacy Policy 

Export Department

Tel. +48 22 313 22 60

Tel. +48 22 313 22 65

e-mail: sales@medima.com.pl

Service Center

Tel./Fax. +48 22 313 22 57

E-mail: service@medima.com.pl

MEDIMA Sp. z o.o.

Al. Jerozolimskie 200

02-486 Warszawa

NIP: 522 - 270 - 98 - 42

KRS: 0000201189

Infusion pumps belong to medical devices group which work effectiveness influences medical procedures safety in much extent. That’s why Medima attaches great importance to safety of use of its products both in terms of reliability and simplicity of use and equipment damages/malfunctions.

 

Our infusion pumps distinguish themselves with following features:  

 

 

Large and colour graphic display with high resolution and contrast. Its great quality allows for infusion status observation from afar and from large acute angles. Additionally its

  properly chosen colour feature increases its projected data legibility

 

User’s interface based upon touch screen and alphanumeric keyboard provides the fastest and exceptionally intuitive way of pump’s handling. Depending on personal preferences

  user can use different ways of parameter values input. Due to context menu and highly functional interface, all the most important functions are quickly available as soon as displayed

  objects are touched and do not require long unintuitive menu lists searching 

 

Automatic syringe installation system is the fastest and the safest way of pump preparation for infusion. There is no possibility of leaving an installed syringe in the pump unprotected

  while possible for manual solutions. System completely eliminates possibility of uncontrolled gravitational infusion.

 

Automatic system of administration set installation in volumetric pumps greatly simplifies and shortens preparation time of our pumps for infusion start. Risk of uncontrolled

  gravitational infusion due to improper administration set installation has been totally eliminated. Additionally pumps produced by Medima start tests of correct action during each

  infusion performance without its interruption.  

 

Exceptional regularity of infusion both in syringe and volumetric pumps guarantees their efficiency when great stability of infusion with small flow rates is expected. It is especially  

  important in case of drug supply with short activity time and in case of low volume drug infusion with long time distribution (Neonatology).

 

Drug library installed in the pumps divided into separate lists of particular wards (CCAs) provides one solution usage for the whole medical administrative unit. Drug library uploading  

  in the pumps is automatic and invisible for users with infusion not needed to be stopped while already started. 5000 drug dosing procedures together with soft and hard limits, low

  and high limits, titration limits, advisory notes, increase safety of infusion fulfilling expectations of the biggest and the most demanding medical centers.

 

Fact of integration necessity is practically one of the requirements for the medical devices groups at the moment. Our pumps installed in our docking stations automatically connect

  with MedimaNet network system which allows for monitoring and archiving of performed infusions and integration with hospital data bases (HIS/PDMS). They also provide

  cooperation with our specialized software modules such as Medima Drug Editor, Medima Configurator, Medima Service & Maintenance which complement functional infusion

  systems of Medima.

 
X
Password:
Wrong password.