+48 22 313 22 66

Infusion Pumps

Sx00/Px00 Family

Syringe Infusion Pumps

Medima S100

 

Basic model, extremely simple to use. Operates in ml/h.

 

Calculates flow rate basing on volume and delivery time.

 

Infusion start combined with a syringe installation takes a couple of seconds only.

 

 

Medima S200

 

Infusion flow rate programmable in ml/h and other frequently used units including: ng,

   µg, mg, g, µEg, mEg, Eg, mIU, IU, kIU, mIE, IE, kIE, mmol, mol, cal, kcal, J, kJ.

   Unit/kg, lb, in², m²/ min, h, 24h.

 

Numerous infusion modes such as: continuous infusion, bolus infusion, infusion with

   profile (up to 24 cycles), TPN.

 

Comprehensive configuration options: advanced protection system, night mode, alarm

   options.

 

Medima S300

 

All options of Medima S200 plus drug library consisting of 6000 full protocols of drugs

   supply (default parameters, soft and hard limits, upper and lower limits), advisory  

   notes, protection functions.  

 

One library for the whole hospital divided into a list of drugs for particular hospital

   wards.

 

Drugs sorted into categories of their activity.

 

A number of other functions increasing infusion's safety.  

 

Medima S300PCA

 

Designed to fight against acute pain. Equipped with a patient-operated button which

   starts the delivery of programmed drug dose and a syringe cover with a lock.

 

An option to switch to standard infusion modes same as for model S300.

 

All options of Medima S300 including drug library with infusion parameter limits.

 

Versions with or without syringe cover.

 

Medima S300TCI

 

Designed for anesthetic applications with bulit-in pharmacokinetic models of drugs.

 

All options of Medima S300

Basic functions

 

All Medina pumps are operated in the same manner (differences between models considered) and have a number of common features:

 

Large and colour graphic touch pad display. 

 

Wide range of syringes with volumes of 2, 5, 10, 20, 30, 50 ml. 

 

Automatic syringe loading and recognition simplifying and speeding up pump maintenance, reducing the initial infusion errors. 

 

Simple to set up and easy to operate. Quick data entry with the use of numerical keyboard. All parameters can be adjusted without infusion interruption. 

 

Different infusion units ng, µg, mg, g, µEg, mEg, Eg, mIU, IU, kIU, mIE, IE, kIE, mmol, mol, cal, kcal, J, kJ. Unit/kg, lb, in², m²/ min, h, 24h.  

 

Data lock. Programmed parameters can be password-protected. Additionally sophisticated function protection system allows blocking access to chosen functions, i.e. infusion start,  

   bolus start, occlusion threshold change, pump switching-off.

 

Bolus fully automatic and manual. Possibility of programming dose, time or flow rate. 

 

Automatic reduction of residual bolus after occlusion release. 

 

12 levels of occlusion pressure. Possibility to adjust the pressure level during infusion. Pressure indication displayed constantly during delivery. 

 

Sophisticated system of alarms. Allows different tones and loudness. Built in night mode with the option to set lower sound level as well as reduce display brightness. 

 

Event log. Allows storing full infusion history (parameters, operator activities and alarms along with the date and time of occurrence). The stored information can be viewed either on  

    the pump's display or on PC.

 

Drug library. 

Volumetric Infusion Pumps

Medima P100

 

Basic model, extremely simple to use. Enabling infusion in ml/h.

 

Calculates flow rate basing on volume and delivery time.

 

Infusion start combined with IV set installation takes a couple of seconds only.

 

Medima P200

 

Infusion flow rate programmable in ml/h and other frequently used units including:

   ng, µg, mg, g, µEg, mEg, Eg, mIU, IU, kIU, mIE, IE, kIE, mmol, mol, cal, kcal, J, kJ.

   Unit/kg, lb, in², m²/ min, h, 24h.

 

Numerous infusion modes such as: continuous infusion, bolus infusion, infusion with

   profile (up to 24 cycles), TPN.

 

Comprehensive configuration options: advanced protection system, night mode, alarm

   options.

 

Medima P300

 

All options of Medima P200 plus drug library consisting of 6000 full protocols of drugs

   supply (default parameters, soft and hard limits, upper and lower limits), advisory    

   notes, protection functions.  

 

One library for the whole hospital divided into a list of drugs for particular hospital

   wards.

 

Drugs sorted into categories of their activity.

 

A number of other functions increasing infusion's safety.  

 

Medima P300PCA

 

Designed to fight against acute pain. Equipped with a patient-operated button which

   starts the delivery of programmed drug dose and a syringe cover with a lock.

 

An option to switch to standard infusion modes same as for model P300.

 

All options of Medima P300 including drug library with infusion parameter limits.

 

Medima P300TCI

 

Designed for anesthetic applications with bulit-in pharmacokinetic models of drugs.

 

All options of Medima P300 including drug library with infusion parameter limits.

 

 

Basic functions

 

All Medina pumps are operated in the same manner (differences between models considered) and have a number of common features: 

 

Large and colour touch pad display. 

 

Simple to set up and easy to operate. Quick data entry with the use of numerical keyboard. All parameters can be adjusted without infusion interruption. 

 

Different infusion units ng, µg, mg, g, µEg, mEg, Eg, mIU, IU, kIU, mIE, IE, kIE, mmol, mol, cal, kcal, J, kJ. Unit/kg, lb, in², m²/ min, h, 24h.  

 

Data lock. Programmed parameters can be password-protected. Additionally sophisticated function protection system allows blocking access to chosen functions, i.e. infusion  

    start, bolus start, occlusion threshold change, pump switching-off.

 

Bolus fully automatic and manual. Possibility of programming dose, time or flow rate. 

 

Automatic reduction of residual bolus after occlusion release. 

 

12 levels of occlusion pressure. Possibility to adjust the pressure level during infusion. Pressure indication displayed constantly during delivery. 

 

Sophisticated system of alarms. Allows different tones and loudness. Built in night mode with the option to set lower sound level as well as reduce display brightness. 

 

Event log. Allows storing full infusion history (parameters, operator activities and alarms along with the date and time of occurrence). The stored information can be viewed either  

   on the pump's display or on PC.

 

Drug library.  

MEDIMA © 2015    •   Privacy Policy 

Export Department

Tel. +48 22 313 22 60, E-mail: sales@medima.com.pl

Tel. +48 22 313 22 65

Service Center

Tel./Fax. +48 22 313 22 57, E-mail: serwis@medima.com.pl

MEDIMA Sp. z o.o. 

Al. Jerozolimskie 200

02-486 Warszawa

NIP: 522 - 270 - 98 - 42

KRS: 0000201189

      Infusion pumps belong to medical devices group which work effectiveness influences medical procedures safety in much extent. That’s why Medima attaches great importance to safety of use of its products either in terms of reliability and simplicity use or equipment damages/malfunctions. Our infusion pumps distinguish themselves with following features:  

 

Large and colour and high resolution graphic display. Its great quality allows for infusion status observation from afar. Additionally its properly chosen colour feature increases its

   projected data legibility.

 

User’s interface based upon touch pad and numeric keyboard provides the fastest and exceptionally intuitive way of pump’ handling. All the most important functions are available

   as quick as displayed objects are touched and do not require long unintuitive Menu lists searching.

 

Automatic syringe installation system is the fastest and the safest way of pump preparation for infusion. There is no possibility of leaving an installed syringe in the pump

   unprotected while possible for manual solutions. System completely eliminates possibility of uncontrolled gravitational infusion.

 

Automatic installation system of IV set in volumetric pumps greatly simplifies and shortens time use of our pumps. Risk of uncontrolled gravitational infusion due to improper IV

   set installation has been totally eliminated. Additionally pumps produced by Medima start tests of correct action during each infusion performance.  

 

Exceptional regularity of infusion either in syringe or volumetric pumps guarantees their efficiency when great stability of infusion with small flow rates are expected. It’s especially

   important in case of drugs supply with short time distribution and in case of low volume drugs infusion with long time distribution (Neonatology).

 

Drugs library installed in the pumps being divided into separate lists of particular wards (Care Units) provides one solution usage for the whole hospital. Drugs library uploading in

   the pumps is automatic invisible for users with infusion not needed to be stopped while already started. 6000 procedures of drugs supply together with soft and hard limits, min.

   and max. limits, advisory notes and additional parameters increase safety of infusion fulfilling expectations of the biggest and the most demanding medical centres.

 

Fact of integration necessity is practically one of the requirements for the medical devices groups at the moment. Our pumps installed in our docking stations automatically

   connect with our net system  program MedimaNet which allows for preview and archiving of performed infusions and integration with hospital data bases. They also provide

   cooperation with our specialized software modules such as Medima Drug Editor, Medima Configurator, Medima Service & Maintenance which complement functional infusion

   systems of Medima.

 
X
Password:
Wrong password.